Pre-Neurointerventional 2D Time of Flight Protocol
Philips 1.5T Achieva and Philips 3T
1. Torso Coil
1. BFFE Survey- 3 plane (BTFE for 3T)
2. Axial SSTSE
3. Axial 2DTOF (M2DIGS TOF for 3T)
a. 2 mm or less slice thickness
b. Inferior regional saturation (REST) slab
1. Images must extend from above the aortic bifurcation to below the femoral heads.
2. Create 2DTOF MIP images and send to PACS.